ROS 2 Haptics Enable Shared Control for Surgical Robot Teleoperation Research

ROS 2 Haptics Enable Shared Control for Surgical Robot Teleoperation Research

Balint Varga, Sebastian Fritz, Gergely Kiss, Kristof Takacs, Peter Galambos

8 min read•Nov 21, 2026

A new open-source ROS 2 framework connects a compact Haply Inverse3 haptic device to the da Vinci Research Kit (dVRK), letting researchers test hands-on guidance for surgical robot control. In a study with 20 participants, the simplest guidance mode significantly reduced wire contacts and task time compared with manual control. The integration also ran on physical dVRK hardware, creating a reusable starting point for further experiments.

What Did the Researchers Build?

The team built an open-source software bridge between the Haply Inverse3, a compact haptic device, and the da Vinci Research Kit, an accessible research platform based on surgical robot hardware. The Inverse3 senses a user’s movement and can apply forces back to their hand. Because it has three degrees of freedom while the dVRK controls a six-degree-of-freedom instrument, the setup combines its position sensing with orientation tracking from Haply’s VerseGrip attachment.

The bridge is designed for ROS 2, the software framework used by many robotics research and development teams. A ROS 2 driver wraps the Inverse3 manufacturer’s WebSocket-based interface and publishes device position, velocity, orientation, and input states. Researchers can send commands either as forces or as target positions; in position mode, a software controller calculates corrective forces to move the haptic handle toward the target.

To demonstrate the system, the researchers added two ways to guide users through a hot-wire task: moving a tool along a wire without touching it. One mode applies guidance that grows with distance from the desired path. The other changes the guidance stiffness as the tool approaches that path. These are reference examples—not a claim that either guidance strategy is ready for clinical use.

Haply Inverse3 and VerseGrip connected for haptic teleoperation of the da Vinci Research Kit

What Were the Key Results?

In a controlled user study, all 20 participants tried three conditions: manual control without active guidance, linear haptic guidance, and progressive-stiffness guidance. The participants ranged in age from 25 to 65, and the order of conditions was balanced to reduce the effect of practice. Researchers measured how many times the tool contacted the wire and how long each task took.

The linear guidance mode significantly improved both measured outcomes compared with manual control: participants made fewer wire contacts and completed the task faster. The progressive-stiffness mode showed similar directional trends, but its results did not meet the study’s corrected statistical significance threshold. That difference matters: adding a more elaborate force profile did not produce a demonstrated benefit over the simpler option in this experiment.

Questionnaire responses also pointed toward higher perceived agency and satisfaction with haptic guidance, but those differences were descriptive rather than established as statistically significant in the supplied results. The study report available here does not include outcome averages, effect sizes, or p-values, so the size of the improvements cannot be quantified or compared numerically with other systems.

The software was also connected to a physical dVRK setup, where researchers demonstrated guidance along a wire trajectory. That demonstration supports the feasibility of transferring the integration beyond a simulated environment, but it is not a second controlled performance evaluation.

How Does the Haptic Control System Work?

The Inverse3 acts as the operator’s hand-held input device. Its position and movement are read through a ROS 2 driver, while the VerseGrip adds orientation sensing and discrete input states. A mapping pipeline translates this input into commands for the dVRK. This lets the framework connect a compact, three-degree-of-freedom haptic device to a robot platform that controls instrument position and orientation across six degrees of freedom.

The software supports two command styles. In force-based control, a ROS 2 command specifies the force to apply directly to the haptic handle. In position-based control, the driver uses a proportional-integral-derivative (PID) controller—a common feedback method that calculates corrective action from the difference between a target and the current position. The control cycle is tied to the timing of messages from the device’s WebSocket service, so its effective update rate depends on that service and the connected hardware.

For the hot-wire task, the guidance force is based on the tool’s distance from the desired wire path. The linear mode provides a direct relationship between distance and guidance force. The progressive-stiffness mode varies the force profile near the path, aiming to balance helpful guidance with the user’s ability to make small corrections. Both modes used matched maximum forces, so the comparison did not simply give one mode a higher force ceiling. The operator remains in control: guidance nudges the user rather than autonomously moving the surgical instrument.

The driver includes operational safeguards. It checks connected hardware and calibration status during startup, limits output force on each axis, and sets force output to zero if commands become stale. A separate configurable timeout can shut down the driver if communication is lost. These are practical protections for a research integration, not a substitute for medical-device safety validation.

Why Does This Matter for Robotics?

Robotics teams often need to experiment with new control ideas without rebuilding the hardware and software connection for every project. This framework packages the link between a commercially available haptic device and the dVRK as an open-source, ROS 2-native integration. That can make it easier to compare guidance methods, add sensors, and share experimental setups across labs using compatible systems.

The study also offers a useful design lesson: simpler haptic guidance performed more reliably than a more complicated stiffness profile for this group of users and task. In a teleoperation system, adding complexity is not automatically an improvement. A force cue needs to be understandable and helpful while still letting the operator override it—especially when users have different experience levels.

The results are relevant to surgical robotics research, but the hot-wire task is a controlled benchmark, not a clinical procedure. It isolates path following, speed, and collision avoidance, allowing engineers to test those elements under limited visual feedback. The physical dVRK demonstration further shows that the software can support hardware integration, while leaving clinical performance and safety questions unanswered. Teams comparing research hardware with available robot platforms can also browse used robots for sale.

What Are the Limitations and Open Questions?

The user study involved 20 volunteers performing one wire-following task, not surgeons operating in a clinical setting. Participants used a standard 2D monitor without stereoscopic depth cues, and the results do not establish whether the same guidance would help expert users or transfer to more varied surgical tasks. The supplied results summary also omits numerical outcome values and effect sizes, limiting independent assessment of how large the improvements were.

The progressive-stiffness mode did not reach the corrected significance threshold, and the researchers note that its added complexity may have increased cognitive load. The physical dVRK work was a preliminary demonstration rather than a controlled evaluation. The framework’s configurable safety features likewise do not constitute clinical certification.

Next steps identified by the team include stereoscopic virtual reality, adjustable force intensity, motion scaling with singularity avoidance, and mode switching through the VerseGrip. Testing these additions with broader tasks and user groups will be important to determine which features provide measurable value.

What Should Readers Know About the Framework?

Does this system control a surgical robot autonomously? No. It provides force cues to guide a human operator, who retains control of the device.

What hardware does the framework connect? It links the Haply Inverse3 and VerseGrip haptic input device with the da Vinci Research Kit through ROS 2.

Which guidance mode performed best in the user study? Linear guidance significantly reduced wire contacts and completion time compared with manual control; progressive stiffness did not meet the corrected significance threshold.

Does the study show that the system is ready for clinical use? No. It evaluates a research integration and a controlled hot-wire task, not clinical performance or safety.

The work delivers a reusable ROS 2 connection for studying haptic shared control with the dVRK and a compact haptic device. Its user study favors simple linear guidance for the tested task, while the physical hardware demonstration establishes a foundation for further research—not a clinical-ready system.